Material Compatibility
Using the correct pump materials are essential if the pump is to have a long life. This is especially so when handling corrosive liquids. Not only the main pump body material, but also the individual parts such as shaft/bearing/mech seal materials must be correctly specified if the pump is to last a long life.

Preventative Maintenance
Sometimes, scheduled pump maintenance is overlooked and instead left as reactive maintenance, whereby the pump is repaired if/when it fails. The risk of this strategy is that an entire process could be shut down whilst the pump is offline being repaired. The cost of carrying out a periodic maintenance procedure should be weighed up against the cost of a system shutdown should a pump fail. Also bear in mind a planned maintenance cost is likely to be much cheaper than a repair cost. Please refer to any pumps installation manual which will include recommended maintenance schedules.

Operating away from the BEP
泵设计运行在最高效的阿宝int by the manufacturer. If the pumps is run too far away from its efficiency point, this can quickly lead to excess recirculation, heat, radial loss, vibration, high seal temperature and vastly lower efficiency.. If a pump is to be used for varying duty points, we would recommend our high efficiency AVF pump range

Improper Piping
Poor piping layout can have a big effect of the pump's operation and its efficiency. Designs with in-verted "U"s on the suction side can trap air, while designs with a 90 degree bend immediately before the pump can cause turbulence inside the pump. Both could potentially result in suction and cavitation problems for the pump. Inlet pipework should be at least one size bigger than the pump inlet in order to prevent cavitation and allow best efficiency.

不干涸!
Under normal operating conditions, the pumped liquid acts as lubricant between the rotating and stationary parts, and the heat generated by the rotational action is gently taken away by the circulating liquid, But when a pump is starved of liquid, these moving parts generate heat from friction and as the heat builds up, damage will occur. For a mechanical seal pump, running dry could lead to pump cavitation and therefore seal damage. The mechanical seal could also experience thermal shock and under the right conditions could shatter within 30 seconds. With a mag-drive pump, the bearings and shaft can rise in temperature due to the absence of liquid lubrication and subsequently melt the plastic casing.

With the Crest Assoma mag drive range, a patented auxiliary circulations channel runs between the bearing and the magnet capsule. The pressure difference has a convection effect for cooling both the interior and exterior of the bearing thereby preventing the high temperature build up causes from dry running. The key point of this feature though, is that whilst the design allows for increased cooling, there is no reduction in pump efficiency.

More articles on this topic

Editorial: How to Avoid This Vital Problem With Pumps

Editorial: How to Avoid This Vital Problem With Pumps

21.07.2022 -

Cavitation occurs in centrifugal pumps when the available net suction head (NPSHa) is lower than the required net suction head (NPSHr). This leads to the formation and accumulation of bubbles around the impeller eye, which then collapse, causing a series of mini-implosions and significant damage to both the impeller and the casing.

Read more
Delta Supports Intelligent Water Supplies with New Energy Efficient MPD Series Motor-Drive Solution

Delta Supports Intelligent Water Supplies with New Energy Efficient MPD Series Motor-Drive Solution

05.07.2022 -

Delta announces the launch of their MPD Series inverter with motor, suitable for pump and fan applications. The new series delivers the benefits of energy efficiency, intelligent water supply and ease of operation by featuring a Delta MSI class IE5 energy efficiency synchronous reluctance motor coupled with a motor-mounted Delta MP300 variable frequency drive.

Read more
25 Mistakes that will Cost Money – Part 2

25 Mistakes that will Cost Money – Part 2

16.06.2022 -

Over our almost 50 years of processing harsh and acidic chemicals, Crest Pumps has seen fair share of pumps that have been broken due to mismanagement and misinformation. Take a look through part two of their guide of 25 ways to break a pump and see if your business is making the same mistakes.

Read more
25 Mistakes that will Cost Money – Part 1

25 Mistakes that will Cost Money – Part 1

10.06.2022 -

Over almost 50 years of processing harsh and acidic chemicals, Crest Pumps has seen fair share of pumps that have been broken due to mismanagement and misinformation. Take a look through part one of their guide of 25 ways to break a pump and see if your business is making the same mistakes.

Read more